Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.6.R02 page 105
PR 91482
On an OS6600 series switch, when max bandwidth rules with either destination ip, source ip, or source
network group are applied and modified, we may run into no free BDs issue.
Workaround: There is no known workaround at this time.
PR 91691
Upgrading the OS8800 FPGA can fail due to insufficient flash space if the user has added files to the
flash.
Workaround: Upgrade the FPGA via 5.1.5.R04 release or remove all files except those on the original
5.1.6.R01 release. Make sure at least 2.5 Meg of free space is available.
NIs—General
Problem Reports
PR 62573
For the following modules, PAUSE frames are generated per port when the port is oversubscribed: OS7-
ENI-C24 and OS7-ENI-FM12, OS7-GNI-U2, OS8-GNI-C8, OS8-GNI-U8, and OS66-GNI-C2.
Workaround: There is no known workaround at this time.
PR 72828
On an OS7000/8800 switch, oversubscribing the egress gigabit module at a rate exceeding 3:1, results in
higher priority traffic sharing the bandwidth equally with lower priority traffic.
Workaround: There is no known workaround at this time.
PR 73196
The failure of a task on NI may cause unsolicited takeover or reboot of the switch.
Workaround: There is no known workaround at this time.
PR 79427
On an OS7000 series switch, there is a compatibility issue with the latest IXIA release, 3.65. Throughput
test on ENI-C-24 couldn't reach 100 percent.
Workaround: Hash should be manually updated.